THERMOCOUPLE
SIGNAL CONDITIONER
/ TRANSMITTERS
DIN Rail Mount
The INFINITY®
signal conditioners provide high accuracy isolated measurement of thermocouple
sensors. For maximum flexibility, the units feature user configurable
thermocouple types which are fully field scalable.
Two models are available, the DRN-TC which provides an analog output
that is proportional to the input signal and the DRX-TC which uses
a digital RS-485 communication link. Both models can accept 9 different
thermocouple types. Thermocouples supported include J, K, T, E, R, S,
B, N, and J DIN.
The output of DRN-TC can be user set for 0-10 V, 4-20 mA or 0-20
mA. Input scaling and configuration of other operating parameters is accomplished
by connecting to a standard RS232 port of a personal computer and using
the DRN-CONFIG, Windows-based setup software. Once configured the settings
may be stored in non-volatile memory and the unit disconnected from the
PC.
The DRX-TC is a digital signal conditioner which communicates over
an RS-485 communication link. Up to 32 modules may be connected to a single
RS-485 port stretching up to 4,000 ft. Through the use of RS-485 repeaters,
additional modules may be used and further transmission distances are
achievable.
SPECIFICATIONS
Accuracy at 25░C: ▒1░C
Resolution: 0.1░C
Power Consumption: 2 W (84 Ma @ 24 vDC)
Input Types: J, K, T, E, R, S, B, N, J DIN
Input Ranges: See range chart
DRX Output: 2-wire (half duplex) RS-485
DRN Output: 0 to 10 V @ 10 mA max; 0 to 20 mA or 4 to 20 mA, 10
V compliance
Input
|
Range,
░F
|
Range,
░C
|
|
Input
|
Range,
░F
|
Range,
░C
|
J
|
-346 to 1400░F
|
-210 to 760░C
|
|
R S
|
-58 to 3214░F
|
-50 to 1768░C
|
K
|
-454 to 2500░F
|
-270 to 1372░C
|
|
B
|
+212 to 3300░F
|
+100 to 1820░C
|
T
|
-454 to 752░F
|
-270 to 400░C
|
|
N
|
-454 to 2372░F
|
-270 to 1300░C
|
E
|
-454 to 1832░F
|
-270 to 1000░C
|
|
J DIN
|
-328 to 1652░F
|
-200 to 900░C
|
To Order (Specify Model No.) Prices
Shown in U.S. Dollars
Model No.
|
Description
|
Price
|
DRX-TC
|
Digital
signal conditioner with RS-485 output for process signals |
$250
|
DRN-TC
|
Signal
conditioner with analog output for process signals |
$325
|
Each unit supplied
with complete operatorÆs manual.
Ordering
Example: DRX-TC
digital signal conditioner with RS-485 output for process signals ($250),
plus CAT-285 bi-directional RS-232-RS-485 converter for DRX series ($148),
$250 + 148 = $398.
ACCESSORIES
Model No.
|
Description
|
Price
|
DRN-CONFIG-(*)
|
Setup
software for DRN series modules, includes serial connection cable
|
$100
|
DRN-PS-750
|
Power
supply, 115 Vac input, 24 Vdc output @ 750 mA |
$130
|
DRN-PS-1000
|
Power
supply, 95-240 Vac input, 24 Vdc output @ 1 amp |
$150
|
CAT-285
|
Bi-directional
RS-232-RS-485 converter for DRX series |
$148
|
*Specify
"9" for 9-pin
or "25" for
25-pin serial cable.
|